The IE3 electric motor is in line with the third efficiency standard in the provisions of GB 18613-2012"the energy efficiency limit and the energy efficiency rating of small and medium-size three-phase asynchronous motors ".And the improvement of the efficiency in its design is in line with the state's requirements for energy saving and consumption reducing of the manufacturing sector.
Technické údaje
|
Typ no . IE3 |
Jmenovitý výstup |
Hodnocený proud |
Hodnoceno rychlost (r/min) |
Hodnocený proud |
Hodnoceno rychlost (r/min) |
Eff % |
Moc Faktor cos φ |
Hodnoceno Točivý moment N.m |
Uzamčený Točivý moment |
Uzamčený Proud |
Max Točivý moment |
Hluk úroveň LW DB (a) |
Hmotnost (KG) |
|||||
|
KW |
HP |
Ifl 380V a |
Ifl 400V a |
Ifl 420V a |
Ifl 440V a |
Ifl 460V a |
Ifl 480V a |
Hodnoceno Točivý moment Tst/tfl |
Hodnoceno Točivý moment Ist/ifl |
Hodnoceno Točivý moment Tm/tfl |
||||||||
|
380 - 420 v/50Hz |
440 - 480 V/60Hz |
|||||||||||||||||
|
Synchronní rychlost 1500r/min |
||||||||||||||||||
|
IE 3-80 m 2-4 |
0.75 |
1.0 |
1.80 |
1.71 |
1.63 |
1430 |
1.55 |
1.49 |
1.43 |
1715 |
82.5 |
0.75 |
5.01 |
2.30 |
6.60 |
2.30 |
56 |
20 |
|
IE 3-90 S -4 |
1.1 |
1.5 |
2.60 |
2.47 |
2.35 |
1430 |
2.25 |
2.15 |
2.06 |
1715 |
84.1 |
0.76 |
7.35 |
2.30 |
6.80 |
2.30 |
59 |
23 |
|
IE 3-90 l -4 |
1.5 |
2.0 |
3.50 |
3.33 |
3.17 |
1430 |
3.02 |
2.89 |
2.77 |
1715 |
85.3 |
0.77 |
10 |
2.30 |
7.00 |
2.30 |
59 |
26 |
|
IE 3-100 l 1-4 |
2.2 |
3.0 |
4.80 |
4.56 |
4.34 |
1440 |
4.15 |
3.97 |
3.80 |
1725 |
86.7 |
0.81 |
14.6 |
2.30 |
7.60 |
2.30 |
64 |
37 |
|
E3-100L2-4 |
3 |
4.0 |
6.30 |
5.99 |
5.70 |
1440 |
5.44 |
5.20 |
4.99 |
1725 |
87.7 |
0.82 |
19.9 |
2.30 |
7.60 |
2.30 |
64 |
42 |
|
IE 3-112 m -4 |
4 |
5.5 |
8.40 |
7.98 |
7.60 |
1455 |
7.25 |
6.94 |
6.65 |
1745 |
88.6 |
0.82 |
26.3 |
2.20 |
7.80 |
2.30 |
65 |
49 |
|
IE 3-132 S -4 |
5.5 |
7.5 |
11.2 |
10.6 |
10.1 |
1465 |
9.67 |
9.25 |
8.87 |
1755 |
89.6 |
0.83 |
35.9 |
2.00 |
7.90 |
2.30 |
71 |
70 |
|
E3-132M-4 |
7.5 |
10.0 |
15.0 |
14.3 |
13.6 |
1465 |
13.0 |
12.4 |
11.9 |
1755 |
90.4 |
0.84 |
48.9 |
2.00 |
7.50 |
2.30 |
71 |
84 |
|
IE 3-160 m -4 |
11 |
15 |
21.5 |
20.4 |
19.5 |
1470 |
18.6 |
17.8 |
17.0 |
1760 |
91.4 |
0.85 |
71.5 |
2.00 |
7.70 |
2.30 |
73 |
130 |
|
E3-160L-4 |
15 |
20 |
28.8 |
27.4 |
26.1 |
1470 |
24.9 |
23.8 |
22.8 |
1760 |
92.1 |
0.86 |
97.4 |
2.00 |
7.80 |
2.30 |
73 |
148 |
|
E3-180M-4 |
18.5 |
25 |
35.3 |
33.5 |
31.9 |
1470 |
30.5 |
29.2 |
28.0 |
1760 |
92.6 |
0.86 |
120 |
2.00 |
7.80 |
2.30 |
76 |
192 |
|
IE 3-180 l -4 |
22 |
30 |
41.8 |
39.7 |
37.8 |
1470 |
36.1 |
34.5 |
33.1 |
1760 |
93.0 |
0.86 |
143 |
2.00 |
7.80 |
2.30 |
76 |
206 |
|
E3-200L-4 |
30 |
40 |
56.6 |
53.8 |
51.2 |
1475 |
48.9 |
46.8 |
44.8 |
1770 |
93.6 |
0.86 |
194 |
2.00 |
7.30 |
2.30 |
76 |
275 |
Časté poruchy a řešení
1. zastavení:Motor bez zatížení nemůže začít
Možné důvody
1. obvod rozbité dráty (jeden ze tří je kořen)
2. Když dítě třífázové vinutí fázového vypínače (typ „y“)
3. Napětí napájení a frekvence jsou nesprávné
Zkontrolujte nebo kalibrační metody
1. Zkontrolujte napájecí napětí nebo individuální připojení .
2. Zkontrolujte pojistku, podavače proudu a každou fázi odporu navíjení .
3. Zkontrolujte napětí a frekvenci
2. zastavení:Motorová zatížení se nemůže začít při nízkém zatížení nebo bez zatížení, kdy, ale při zvyšování zatížení, které se dokonce zastaví, se zastaví
Možné důvody
1. nízkonapěťové napájení
2. Skupina se otočí kolem syna mezi zkrat
3. Statotor třífázový vinutí linie přestávky mimo fázi ("a" pak metoda)
4. přetížení
Zkontrolujte nebo kalibrační metody
1. Zkontrolujte napětí řádku;
2. Zkontrolujte každé fázové vinutí a každou fázi bez zatížení;
3. Zkontrolujte každou odolnost proti vinutí fáze;
4. Zkontrolujte zatížení
Populární Tagy: Elektrický motor IE3, Čína IE3 Výrobci elektrického motoru, továrna